Symmetry-Breaking-Based Fault Localization in Dual Active Bridge Converters at the Unity-Gain Boundary
Published in Zhejiang Power Electronics Conference (ZPEC), 2026
This paper proposes an enhanced fault localization strategy for Dual Active Bridge (DAB) converters based on transient symmetry breaking. The proposed method addresses the mathematical singularity at the unity-gain boundary ($k = 1$), where primary- and secondary-side open-circuit fault signatures become indistinguishable in frequency-domain diagnostics. When a fault is detected near $k \approx 1$, a controlled adjustment of the voltage ratio and phase shift is introduced to separate the overlapping harmonic signatures, restoring fault discriminability without additional sensors or power interruption. Validation on a 7 kW DAB system demonstrates that the proposed approach expands the discriminability margin from 0.01 to 0.15 and achieves accurate fault identification with approximately 4 ms latency, providing a cost-effective software-based solution for improving DAB converter reliability across the full operating range.
Recommended citation: Krishna Laksheta, Y. F. Sidik, and F. D. Wijaya, "Symmetry-Breaking-Based Fault Localization in Dual Active Bridge Converters at the Unity-Gain Boundary," Zhejiang Power Electronics Conference (ZPEC), 2026.